Westermo ODW-620-F1 User Manual

Browse online or download User Manual for Equipment Westermo ODW-620-F1. Westermo ODW-620-F1 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
©
Westermo Teleindustri AB
User Guide
6651-22621
www.westermo.com
Industrial Converter
Serial RS-232 to fibre optic link
Point-to-point applications
ODW-620-F1
Fibre Optic Modem
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - ODW-620-F1

©Westermo Teleindustri ABUser Guide6651-22621www.westermo.comIndustrial Converter Serial RS-232 to fibre optic link Point-to-point applicationsODW-6

Page 2 - Legal information

106651-22621Designed for harsh environments, such as industrial, road and railway applicationsThe ODW-620-F1 complies with standards for industrial e

Page 3

116651-22621Status Port type Signal relay, changeover contactsRated voltage Up to 48 VDCOperating voltage Up to 60 VDCContact rating 500 mA @ 48 VDCCo

Page 4 - Note. Fibre Optic Handling

126651-22621FX (Fibre) SM-LC80 SM-LC40 SM-LC15 MM-LC2Fibre connector LC duplex LC duplex LC duplex LC duplexFibre type Singlemode 9/125 mmSinglemode 9

Page 5 - Declaration of conformity

136651-22621Location of Interface ports, LED’s and DIP-switchesPosition Direction* DescriptionD-sub1 Out Data Carrier Detect (DCD)2 Out Received Data

Page 6

146651-22621LED indicators LED Status DescriptionPWR PowerON In service (power)Flashing Fault conditionOFF Out of serviceRDR OFF Not usedCH 2 OFF Not

Page 7 - Functional description

156651-22621ConfigurationAll needed configurations and parameter settings are done by the DIP-switches, located under the top lid.!DIP-switch settings

Page 8

166651-22621CoolingThis unit uses convection cooling. To avoid obstructing the air-flow around the unit, use the following spacing rules. Minimum spac

Page 9

176651-22621Configure the ODW-620-F1s. Using the factory DIP-switch settings, set: …S1: CTS always active or RTS/CTS control. …Connect The fibre link

Page 12

26651-22621Legal informationThe contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, eithe

Page 13

REV.A 6651-22621 2012-12 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group CompanyWestermo • SE-640 40 Stora Sundby, SwedenTel +46 16

Page 14 - LED indicators

36651-22621SafetyBefore installation:Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check

Page 15 - Configuration

46651-22621Note. Fibre Optic HandlingFibre optic equipment requires careful handling as the fibre components are very sensitive to dust and dirt. I

Page 16 - Mounting

56651-22621Declaration of Conformity Westermo Teleindustri AB Declaration of conformity Org.nr/ Postadress/Postal address Tel. Telefax Pos

Page 17 - Master Slave

66651-22621Type tests and environmental conditionsElectromagnetic CompatibilityPhenomena Test Description LevelESD EN 61000-4-2 Enclosure contact ± 6

Page 18

76651-22621 STATUS C NO NC LED’s Switches CH 1 SFP Fibre transceiver TX RX Internal Electronics RS -232 SHIELD DCD RD TD SG DSR RTS CTS ODW-62

Page 19

86651-22621Point-to-point communication via fibre optical network The serial data is transferred via a fibre optic network between two ODW-620-F1. Th

Page 20

96651-22621Optical fibre link functionality and status indicationAt power on, all LED’s will be active during an initiation sequence followed by an au

Related models: ODW-621

Comments to this Manuals

No comments