Westermo TD-22 User Manual

Browse online or download User Manual for Equipment Westermo TD-22. Westermo TD-22 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 51
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
PTT Modem
INSTALLATION MANUAL
6177-2203
www.westermo.se
TD-22 AC
TD-22 DC
©
Westermo Teleindustri AB • 1998 • REV A
Galvanic
Isolation
Transient
Protection
CE
Approved
Page view 0
1 2 3 4 5 6 ... 50 51

Summary of Contents

Page 1 - INSTALLATION MANUAL

PTT ModemINSTALLATION MANUAL6177-2203www.westermo.seTD-22 ACTD-22 DC©Westermo Teleindustri AB • 1998 • REV AGalvanicIsolationTransientProtectionCEAppr

Page 2

116177-2203LED Status IndicatorsPWR: Full Intensity The modem is functioning normallyHalf intensity The modem is in test mode or remote configuration

Page 3 - Introduction

12 6177-2203DTE Command LinesA command line is a string of characters sent from a DTE to the modem (DCE) while the modem isin a command state. A comma

Page 4 - Installation

136177-2203AT COMMAND SETThe modem will respond to the commands detailed below. Parameters applicable to each commandare listed with the command descr

Page 5 - Line connection

14 6177-2203&Bn – DTR Dial OptionThis command interprets the OFF to ON transition of the DTR signal from the DTE to enable themodem to dial the te

Page 6 - 76177-2203

156177-2203Dn – DialThis command directs the modem to go on-line, dial according to the string entered and attempt toestablish a connection. If no dia

Page 7 - DIP Switch Setup

16 6177-2203&Dn – DTR OptionThis command interprets the ON to OFF transition of the DTR signal from the DTE in accordancewith the parameter suppli

Page 8 - 96177-2203

176177-2203%En – Enable/Disable Line Quality Monitor and Auto-Retrain or Fallback/Fall Forward (V.22bis only)Controls whether or not the modem will au

Page 9 - 10 6177-2203

18 6177-2203%Fn – Split-Speed direction select, V.23Determines which direction (transmit or receive) has the 75bps channel and which has the 1200bpsch

Page 10 - LED Status Indicators

196177-2203Hn – Disconnect (hang up)This command initiates a hang up sequence.This command may not be available for some countries due to PTT restrict

Page 11 - DTE Command Lines

20 6177-2203\Kn – Break ControlControls the response of the modem to a break received from the DTE or the remote modem or the\B command according to t

Page 12 - 136177-2203

36177-2203TABLE OF CONTENTSINTRODUCTION ...

Page 13 - &Cn – DCD Option

216177-2203Ln – Speaker VolumeThe modem sets the speaker volume control according to the parameter supplied. The parametervalue, if valid, is written

Page 14 - Dn – Dial

22 6177-2203*L – Display secure access (callback) directoryThe modem will display all secure access (callback) directory entries.Format: Entry Number

Page 15 - En – Command Echo

236177-2203&Mn – Asynchronous/Synchronous Mode SelectionThis command determines the DTR operating mode. The modem treats the &M command as a s

Page 16 - Fn – Select Line Modulation

24 6177-2203\Nn – Operating ModeThis command controls the preferred error correcting mode to be negotiated in a subsequent dataconnection. This comman

Page 17 - &Gn – Select Guard Tone

256177-2203Qn – Quiet Results Codes ControlThe command enables or disables the sending of result codes to the DTE according to the parametersupplied.

Page 18 - &Kn – Flow Control

26 6177-2203&Rn – RTS/CTS OptionThis selects how the modem controls CTS. CTS operation is modified if hardware flow control isselected (see &K

Page 19 - -Kn Extended Services

276177-2203&Sn – DSR OverrideThis command selects how the modem will control DSR. The parameter value, if valid, is written toS21 bit 6.&S0 DS

Page 20 - Ln – Speaker Volume

&Tn – Test and DiagnosticsThe modem will perform selected test and diagnostic functions according to the parameter supplied.A test can be run only

Page 21 - Mn – Speaker Control

296177-2203&V – Display Current Configuration and Stored ProfilesReports the current (active) configuration, the stored (user) profiles, and the f

Page 22 - Nn – Automode Enable

30 6177-2203\W – Split Speed OperationThis command supports a split-speed DCE/DTE interface for applications such as Viewdata terminalswhich require a

Page 23 - \Nn – Operating Mode

4 6177-2203IntroductionThe Westermo TD-22 is an industrialised dial and leased line modem. This modem has beendeveloped to be used in industrial appli

Page 24 - %Q – Line Signal Quality

316177-2203&Xn – Select Synchronous Clock SourceSelects the source of the transmit clock for the synchronous mode of operation. The parameter valu

Page 25 - Sn – Read/Write S-Register

32 6177-2203Zn – Soft Reset and Restore ProfileThe modem performs a soft reset and restores (recalls) the configuration profile according to theparame

Page 26 - &Sn – DSR Override

336177-2203Result CodesWhen a command is sent from the terminal the modem replies with a result code. The reply may beeither in Long Form i.e. text (V

Page 27 - Vn – Result Code Form

34 6177-2203S-REGISTERSBelow follows a description of the S-registers and its different components. Note that someparameters can not be changed due to

Page 28 - Wn – Connect Message Control

356177-2203S10 – Lost Carrier To Hang Up DelaySets the length of time, in tenths of a second, that the modem waits before hanging up after a loss ofca

Page 29 - Xn – Extended Result Codes:

36 6177-2203S16 – General Bit Mapped Test Options Status (&T) (Read only register, not stored with &W)Indicates the test in progress status. B

Page 30 - Yn – Long Space Disconnect

376177-2203Bit 5 RLSD (DCD) behaviour (&Cn)0 = &C0 selected (Default.)1 = &C1 selectedBit 6 DSR behaviour (&Sn)0 = &S0 selected

Page 31 - 32 6177-2203

38 6177-2203Bits 6-7 Guard tone (&Gn)0 = None (&G0)1 = None (&G1)2 = 1800 Hz (&G2) (Default.)S24 – Receiver disconnect levelIf %D1 is

Page 32 - Result Codes

396177-2203S29 – Flash Dial Modifier Time (Not stored with the AT&W command. Only for Germany)Sets the length of time that the modem will go on-ho

Page 33 - S-REGISTERS

40 6177-2203S38 – Delay Before Forced Hang Up (Not stored with the AT&W command!)This register specifies the delay between the modem's receip

Page 34 - 356177-2203

56177-2203SpecificationsInstallationThe modem should beconnected in the followingway:Power connection is madethrough screw-block at bottomright corner

Page 35 - 36 6177-2203

416177-2203Bit 3 Modem-to-modem flow control0 = Disabled (\G0) (Default.)1 = Enabled (\G1)Bits 4-5 ReservedBit 7 Enable fallback to V.22 bis/V.22 (

Page 36 - 376177-2203

42 6177-2203S200 – Bit Mapped RegisterBit 0 If not set is normal faxspeeeds used, or else it is a special function.Bit 6 and 7 Equal to \C command (No

Page 37 - 38 6177-2203

436177-2203Example1:Several commands can be stacked on each command-line. For exampleATEQ1\N4D12345can be used instead of ATE0OKATQ1OKAT\N4OKATD12345w

Page 38 - 396177-2203

To use multidrop V23 in half duplexMultidrop connection is possible only when the modem is set for V23 half duplex. This allows amaximum line transmis

Page 39 - 40 6177-2203

456177-2203Dial up with hardware signallingDial-up can be made by applying an external signal to the DTR-pin in the RS-232 contact. A typicalapplicati

Page 40 - 416177-2203

Leased line applicationsLeased line connections can be done using either 2-wire or 4-wire.When renting a 4-wire line from a telephone company one pair

Page 41 - Block diagram

476177-2203GlossaryASCIIA binary code system which defines 128 characters using different combinations of 1s and 0s. ASCII= American Standard Code for

Page 42 - Example1:

48 6177-2203V.42bis.Data Compression technique used by modems rather than MNP5, because it offers bettercompression on already compressed data.Data Ra

Page 43 - 44 6177-2203

496177-2203Modulation TechniquesDPSKDifferential Phase Shift Keying. employed in data rates up to 4800bps.FSKFrequency Shift Keying. Used in the lowes

Page 44 - External signal

50 6177-2203RS232 SignalsTDTransmitted Data. Data going from DTE to DCE.RDReceived Data. The Data going from DCE to DTE.RTSRequest to Send. Hardware

Page 45 - Leased line applications

25 Pin Screw Direction Name DescriptionD-sub Terminal DCE-DTE1 - - - PE Protective earth2 8 TXD Transmit data3 7 RXD Receive data4 6 RTS Request to

Page 46 - Glossary

516177-2203OWN COMMENTS...

Page 47 - 48 6177-2203

6177-2203 11.98 TunaTryck AB, Eskilstuna, SwedenWestermo Teleindustri AB • S-640 40 Stora Sundby, SwedenPhone +46 16 612 00 Fax +46 16 611 80E-mail: i

Page 48 - 496177-2203

76177-2203Typical TD-22 line connections4-positionscrew-terminalHandshakingLeased line 2-wireTelephoneexchangeTelephoneexchangeDial up line 2-wireTele

Page 49 - 50 6177-2203

8 6177-2203DIP Switch SetupDisconnect power before changing DIP-switches.Take ESD-protection when changing switches.The DIP-switches can be used to pr

Page 50 - OWN COMMENTS

96177-2203SW4:87654321Select speed and parity towardscomputer/terminal0 0 0 0 Automatic speed and format setting up0 0 0 1 300 Baud0 0 1 0 600 Baud0 0

Page 51 - Subsidiaries

10 6177-22038765321Select Line Modulation0 0 0 Use saved parameters0 0 1 V.21 300 bps (0-300) ATF10 1 0 V.23 Hdx ATF3 %F30 1 1 V.23 1200/75 bps ATF31

Comments to this Manuals