Westermo ODW-730-F2 User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
12
6651-2255
Data transport in multidrop, dual channel, V-mode configuration
RX2
TX2
Device 1
Sending data to
device 3 and 4 on the
primary channel
Device 2
Sending data to
device 5 on the
secondary channel
Device 3
Receiving data from
device 1 on the
primary channel
Device 5
Receiving data from
device 2 on the
secondary channel
TX1
RX1
RX2
TX2
TX1
RX1
RX2
TX2
RS-485 RS-485 RS-485
Fibre
pair
Fibre
pair
Fibre
pair
RS-485
TX1
RX1
RX2
TX2
TX1
RX1
PWR
FP
TD
RD
PWR
FP
TD
RD
PWR
FP
TD
RD
PWR
FP
TD
RD
Device 4
Receiving data from
device 1 on the
primary channel
RS-485
Fibre
pair
RX2
TX2
TX1
RX1
PWR
FP
TD
RD
The first ODW-730 unit recieives data from communications device 1 on the RS-485
port and sends it out on optical fibre TX1 using the primary data channel.
The second ODW-730 unit receives primary channel data on optical fibre RX2. Primary
channel data is repeated out on optical fibre TX1. The second ODW-730 unit also
receives data from communications device 2 on the RS-485 port. The RS-485 data is sent
out on optical fibre TX1 using the secondary data channel.
The third and fourth ODW-730 units receive both primary and secondary channel data
on optical fibre RX2. Both primary and secondary data are repeated out on optical fibre
TX1, but only the primary channel data is sent out on the RS-485 port.
The fifth ODW-730 unit receives both primary and secondary channel data on optical
fibre RX2, but only the secondary channel data is sent out on the RS-485 port.
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 35 36

Comments to this Manuals