Westermo MR-2x0 User Manual

Browse online or download User Manual for Equipment Westermo MR-2x0. Westermo MR-2x0 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
ANT. WWAN
(Main)
ANT. WWAN
(Aux.)
11 -58V DC
1,3 A
MAIN AUX.
ASY 0
LAN3 LAN2 LAN1 LAN0
MR-270
PWR
NET
SIM
DAT
DTE
SIM 1
SIM 2
3G/GPRS
WLAN
0
1
2
3
LAN
SIGNAL
ANT.
(AUX.)
9-48V
DC
ASY 0
ANT .
(MAIN)
LAN
MR-260
PWR
LAN
WAN
NET
SIM
DAT
DTE
SIM 1
SIM 2
3G/GPRS
SIGNAL
MR-210
GSM/GPRS Router
MR-260
GSM/GPRS/Edge/3G/
HSDPA/HSUPA Router
MR-270
GSM/GPRS/Edge/3G/
HSDPA/HSUPA Router
www.westermo.com
©
Westermo Teleindustri AB
User Guide
6622-2221
29000447
MR-210/260/270
ANT.
(AUX.)
9-48V
DC
ASY 0
ANT .
(MAIN)
LAN
MR-210
PWR
LAN
WAN
NET
SIM
DAT
DTE
SIM 1
SIM 2
GPRS
SIGNAL
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - MR-210/260/270

ANT. WWAN(Main)ANT. WWAN(Aux.)11 -58V DC1,3 AMAIN AUX.ASY 0LAN3 LAN2 LAN1 LAN0MR-270PWRNETSIMDATDTESIM 1SIM 23G/GPRSWLAN0123LANSIGNALANT.(AUX.)9-48VDC

Page 2 - Legal information

10 6622-2221 • -29000447Type tests and environmental conditionsPhenomena Test Description Test levelsESD EN 61000-4-2 Enclosure contact ± 4 kVEnclosu

Page 3 - GSM specific safety

116622-2221 • 29000447DescriptionThe MR-series are cellular enterprise class routers that provide secure remote access solutions that can save time an

Page 4 - 4 6622-2221 • -29000447

12 6622-2221 • -29000447Interface specificationsPowerRated voltage / Operating voltageMR-210 / MR-260 9 – 48 VDCMR-270 11 – 58 VDCRated current (max

Page 5 - Maintenance

136622-2221 • 29000447Antenna Frequency bands 850 MHz – 2100 MHzConnection SMA female, impedance: 50 ohmSIMElectrical specification 3 volts SIM suppor

Page 6 - 6 6622-2221 • -29000447

14 6622-2221 • -29000447RS-232Position Direction Description Connector DescriptionNo. 1 In RTS (Request To Send)1 2 3 4 5 6 7 8No. 2 In DTR (Data Term

Page 7 - Declaration of conformity

156622-2221 • 29000447RS-232Position Direction Description Connector DescriptionNo. 1 Out Data Carrier Detect (DCD)123459 876No. 2 Out Receive Data (R

Page 8

16 6622-2221 • -29000447Description of AUX-connector and I/O signal linesThe auxiliary power connector has two programmable signal lines. One is an in

Page 9

176622-2221 • 29000447If the auxilary power connector is being used, the main power connector should NOT be used.Input Signal Information… Applied i

Page 10

18 6622-2221 • -29000447LED Indicators MR-210 / MR-260LED Status DescriptionPWR OFF Unit has no powerGREEN All OKRED Lit until unit has started upLAN

Page 11 - Dimensional drawing

196622-2221 • 29000447LED Indicators MR-270LED Status DescriptionPWR OFF Unit has no powerGREEN All OKRED Lit until unit has started upLAN 0,1,2,3 OFF

Page 12 - Interface specifications

2 6622-2221 • -29000447Legal informationThe contents of this document are provided “as is”. Except as required by applicable law, no warranties of any

Page 13 - 136622-2221 • 29000447

20 6622-2221 • -29000447Protocols and FunctionalityEthernet TechnologiesIEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseTXCellular TechnologiesGSM GPRS M

Page 14 - 1 2 3 4 5 6 7 8

216622-2221 • 29000447ManageabilityManagement tools • Web interface (HTTP and HTTPS) • Command Line Interface (CLI) via console port, SSHv2 and T

Page 15 - Connections, MR-270

22 6622-2221 • -29000447Factory default/resetPerform the following 4 steps to reset the unit to its factory default settings.1. Power up the unit.2.

Page 16 - 16 6622-2221 • -29000447

236622-2221 • 29000447Step-by-step guide to configure a GPRS/3G/HSPA connection using the web interfaceANT.(AUX.)9-48VDCASY 0ANT.(MAIN)LANPower Connec

Page 17 - 176622-2221 • 29000447

24 6622-2221 • -29000447Step 3 – Accessing the unitStart a web browser on your PC and type in the following addresshttp://192.168.2.200Step 4 – Login

Page 18 - 18 6622-2221 • -29000447

256622-2221 • 29000447Step 6 – Mobile SetupThen fill in the Service Plan / APN and the SIM PIN number, if the card uses that.First click on Mobile und

Page 19 - LED Indicators MR-270

26 6622-2221 • -29000447It is also recommended to enable the firewall on the unit. However, in some applica-tions there might be a need to open up the

Page 20 - Protocols and Functionality

276622-2221 • 29000447Step 8 – Test your connectionIn your Internet browser type in www.westermo.com and test your connection, you should be able to s

Page 21 - Custom Control

REV.B 6622-2221 29000447 2013-03 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group CompanyWestermo • SE-640 40 Stora Sundby, SwedenTel

Page 22 - Factory default/reset

36622-2221 • 29000447SafetyBefore using this unit:Read this manual completely and gather all information on the unit. Make sure that you understand it

Page 23 - Gateway 192.168.2.200

4 6622-2221 • -29000447GeneralRemember to follow any special regulations and warnings in force in any area and never use the unit whenever it’s forbid

Page 24 - 24 6622-2221 • -29000447

56622-2221 • 29000447For Vehicles equipped with an airbagAn air bag inflates with great force. DO NOT place objects, including either installed or por

Page 25 - Step 6 – Mobile Setup

6 6622-2221 • -29000447FCC Part 15.105 Notice: This equipment has been tested and found to comply with the limits for a Class B digital device, purs

Page 26 - 26 6622-2221 • -29000447

76622-2221 • 29000447Declaration of Conformity, MR-210 Westermo Teleindustri AB Declaration of conformity Org.nr/ Postadress/Postal addres

Page 27 - 276622-2221 • 29000447

8 6622-2221 • -29000447Declaration of Conformity, MR-260 Westermo Teleindustri AB Declaration of conformity Org.nr/ Postadress/Postal addr

Page 28 - Sales Units

96622-2221 • 29000447Declaration of Conformity, MR-270 Westermo Teleindustri AB Declaration of conformity Org.nr/ Postadress/Postal addres

Comments to this Manuals

No comments