Westermo TD-29P User Manual

Browse online or download User Manual for Equipment Westermo TD-29P. Westermo TD-29P User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Multidropp 2-tråd
Multidrop 2-wire
Multidrop 2-Draht
Multipoints 2-fils
INSTALLATIONSANVISNING
INSTALLATION MANUAL
INSTALLATIONS ANLEITUNG
MANUEL D’INSTALLATION
6611-2022
www.westermo.com
TD-29P
FSK-modem
©
Westermo Teleindustri AB • 2004 • REV.A
Galvanic
Isolation
Transient
Protection
Balanced
Transmission
CE
Approved
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - MANUEL D’INSTALLATION

Multidropp 2-trådMultidrop 2-wireMultidrop 2-DrahtMultipoints 2-filsINSTALLATIONSANVISNINGINSTALLATION MANUALINSTALLATIONS ANLEITUNGMANUEL D’INSTALLAT

Page 2 - Contents

GB.24 6611-20222-positionScrew terminal Direction Description1 In/Out2 In/Out9-position ITU-T V.11Screw terminal Direrction Description Description7 I

Page 3 - 1. Safety

GB.256611-20226.7 Configuration6.7.1 DIP switch settingsDIP-switches are accessable under the lid on top of the unit. DIP-switches are used to configu

Page 4 - 2.1 Declaration of Conformity

GB.26 6611-2022Factory settingTermination of RS-485*Character formatS110 bitsON12345678S111 bitsON12345678Selection of Baud rateS19 600 bit/sON1234567

Page 5 - 3. Introduction

GB.276611-20227. Functional description7.1 Block diagram7.2 RS-485 connectionAmplifier S1:6S1:7RDLEDDCDLEDBAScrew terminal123456780VF10V+5V–5V0VS2:4S

Page 6 - 4. Specifications

GB.28 6611-2022POWERLINE CONNECTIONPWRTDRDRTSCTSDCD+–POWERLINE CONNECTIONPWRTDRDRTSCTSDCD+–POWERLINE CONNECTIONPWRTDRDRTSCTS

Page 7 - 4.4 Mechanical

GB.296611-2022OWN COMMENTS...

Page 8 - 6. Installation

T04-0340 • 6611-2022 04.11 Mälartryck AB, Eskilstuna, SwedenWestermo Teleindustri AB • SE-640 40 Stora Sundby, SwedenPhone +46 16 42 80 00 Fax +46 16

Page 9 - 6.2 Connections

GB.16 6611-2022Contents1. Safety ...

Page 10 - 6.6 Power Interface

GB.176611-20222. ApprovalsConformity with the Directive 89/336/EEC Electromagnetic Compatibility (EMC) has been assessed by application of standards E

Page 11 - 123 456789

GB.18 6611-20222.1 Declaration of Conformity

Page 12

GB.196611-20223. IntroductionThe TD-29P is designed for communication on 2-wire copper cable (twisted pair).Multidrop or point to point half duplex co

Page 13 - 7. Functional description

GB.20 6611-20224. Specifications 4.1 InterfacesPowerTD-29P DCRated voltage 24 VDCOperating voltage 12–36 VDCRated current 200 mARated frequency DC (Re

Page 14 - 7.3 Line connection

GB.216611-20224.2 Isolation between interfacesPower to all other 1.5 kV RMS @ 50Hz and 60 s durationFSK-Line to all other 1.5 kV RMS @ 50Hz and 60 s d

Page 15 - OWN COMMENTS

GB.22 6611-20225. MaintenanceNo maintenance is required, as long as the unit is used asintended within the specified conditions.6. Installation6.1 Mou

Page 16 - Subsidiaries

GB.236611-20226.3 LED Status IndicatorsPWR LED on Power onLED off Power offTD LED on Transmit line data activeLED off Transmit line data inactiveRD LE