296195-2201
+ICF – DTE-DCE character framing
This command is used to determine the local serial port start-stop (asynchronous)
character framing that the DCE shall use.
Command syntax: AT+ICF= <format>, <parity>
* <format>:
0 Autodetect Not supported
1 8 Data 2 Stop supported
2 8 Data 1 Parity 1 Stop supported
3 8 Data 1 Stop supported
4 7 Data 2 Stop supported
5 7 Data 1 Parity 1 Stop supported
6 7 Data 1 Stop supported
* <parity>:
0 Odd Supported
1 Even Supported
2 Mark Supported
3 Space Supported
4 None Supported
Note 1) Setting a character framing different from 8N1 will disable autobauding
(in the case it was activated). However setting it back to 8N1 will not re-enable
autobaud.
Note 2) Setting the framing to 8N1 will let the autobauding enabled, if it was already
enabled (implying framing was already 8N1).