Westermo ODW-730-F2 User Manual

Browse online or download User Manual for Equipment Westermo ODW-730-F2. Westermo ODW-730-F2 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
©
Westermo Teleindustri AB
www.westermo.com
Management Guide
6651-2255
Westermo
ODW-730-F2
Industrial Converter
RS-485 to Fibre Optic Link.
Repeater, line and redundant ring
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - ODW-730-F2

©Westermo Teleindustri ABwww.westermo.comManagement Guide6651-2255Westermo ODW-730-F2 Industrial Converter RS-485 to Fibre Optic Link. Repeater, line

Page 2

106651-2255Multidrop, dual channel, V-mode configurationIn dual channel mode it is possible to use two separate data streams in a single ODW-730 netwo

Page 3

116651-2255• Connect the fibre pairs between the units. Always connect CH 1 from one unit to CH 2 on the next unit as shown in the picture above.•

Page 4

126651-2255Data transport in multidrop, dual channel, V-mode configurationRX2TX2Device 1Sending data todevice 3 and 4 on theprimary channelDevice 2Sen

Page 5

136651-2255RX2TX2Device 1Receiving data fromdevice 4 on theprimary channelDevice 2Receiving data fromdevice 5 on thesecondary channelDevice 3Not sendi

Page 6

146651-2255Redundant ring, Y-mode configurationIn a redundant ring an extra fibre pair is used. This extra fibre pair is used to carry data if one of

Page 7

156651-2255Data transport in redundant ring, Y-mode configurationRX2TX2Device 1SendingDevice 2ReceivingDevice 3ReceivingDevice nReceivingTX1RX1RX2TX2T

Page 8

166651-2255RX2TX2Device 1SendingDevice 2ReceivingDevice 3RecivingDevice 4ReceivingTX1RX1RX2TX2TX1RX1RX2TX2RS-485 RS-485 RS-485FibrepairFaultysegmentFi

Page 9

176651-2255Redundant ring, V-mode configurationIn a redundant ring an extra fibre pair is used. This extra fibre pair is used to carry data if one of

Page 10 - 6651-2255

186651-2255adjusted to accommodate these delays if using many ODW-730 units in a large network.See page 32 “Calculating system processing delay” for m

Page 11

196651-2255Data transport in redundant ring, V-mode configurationRX2TX2Device 1SendingDevice 2ReceivingDevice 3ReceivingDevice nReceivingTX1RX1RX2TX2T

Page 12

26651-2255ContentMultidrop, Y-mode configuration ...

Page 13

206651-2255If an optical fibre segment fails, the ODW-730 Ring Focal Point will switch mode and start sending out data on both optical fibre ports, TX

Page 14

216651-2255Redundant ring, dual channel, Y-mode configurationIn a redundant ring an extra fibre pair is used. This extra fibre pair is used to carry d

Page 15

226651-2255• Connect the fibre pairs between the units. Always connect CH 1 from one unit to CH 2 on the next unit as shown in the picture above.• C

Page 16

236651-2255Data transport in redundant ring, dual channel, Y-mode configurationRX2TX2TX1RX1RX2TX2TX1RX1RX2TX2FibrepairFibrepairFibrepairTX1RX1RX2TX2TX

Page 17

246651-2255RX2TX2TX1RX1RX2TX2TX1RX1RX2TX2FibrepairFibrepairFibrepairTX1RX1RX2TX2TX1RX1Primary channelFocal pointScondary channelFocal pointDevice 1Rec

Page 18

256651-2255RX2TX2TX1RX1RX2TX2TX1RX1RX2TX2FibrepairFibrepairTX1RX1RX2TX2TX1RX1Primary channelFocal pointScondary channelFocal pointDevice 1Receiving da

Page 19

266651-2255Redundant ring, dual channel, V-mode configurationIn a redundant ring an extra fibre pair is used. This extra fibre pair is used to carry d

Page 20

276651-2255• Set DIP-switch S2:6 as desired. See page 34 “Status port” for more information.• Verify that DIP-switches S2:1 and S2:8 are set in the

Page 21

286651-2255Data transport in redundant ring, dual channel, V-mode configurationThe first ODW-730 unit recieives data from communications device 1 on t

Page 22

296651-2255The fifth ODW-730 unit recieives data from communications device 5 on the RS-485 port and sends it out on optical fibre TX2 using the secon

Page 23

36651-2255Multidrop, Y-mode configurationIn Y-mode mode an ODW-730 network will behave as a 2-wire bus. I.e. all communica-tion devices will “hear” th

Page 24

306651-2255If an optical fibre segment fails, the ODW-730 Ring Focal Points will switch mode and start sending out data on both optical fibre ports, T

Page 25

316651-2255LED indication during optical link failureRX2TX2TX1RX1RS-485PWRFPTDRDRX2TX2TX1RX1RS-485PWRFPTDRDRX2TX2TX1RX1RS-485PWRFPTDRDRX2TX2TX1RX1RS-4

Page 26

326651-2255Calculating system processing delayData exchange between commuinication devives via an ODW-730 fibre optic link, will be delayed due to the

Page 27

336651-2255Reconfiguration time under faulty conditionThe reconfiguration time is determined by the time it takes to detect a faulty fibre seg-ment pl

Page 28

346651-2255About the interfacesPower terminalThe power terminal has two independent inputs, +VA and +VB, allowing redundancy should either fail. The O

Page 30

REV.B 6651-2255 2012-11 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group CompanyWestermo • SE-640 40 Stora Sundby, SwedenTel +46 16

Page 31

46651-2255Data transport in multidrop, Y-mode configurationRX2TX2Device 1SendingDevice 2ReceivingDevice 3ReceivingDevice nReceivingTX1RX1RX2TX2TX1RX1R

Page 32

56651-2255Multidrop, V-mode configurationIn V-mode an ODW-730 network will behave as a 4-wire bus. Where the first ODW-730 (leftmost in the picture be

Page 33

66651-2255Data transport in multidrop, V-mode configurationRX2TX2Device 1SendingDevice 2ReceivingDevice 3ReceivingDevice nReceivingTX1RX1RX2TX2TX1RX1R

Page 34 - About the interfaces

76651-2255Multidrop dual channel, Y-mode configurationIn dual channel mode it is possible to use two separate data streams in a single ODW-730 network

Page 35

86651-2255Note: In an ODW-730 fibre optic network there will be some additional processing delays that do not exist in an electrical bus. It is possi

Page 36 - Sales Units

96651-2255Data transport in multidrop, dual channel, Y-mode configurationRX2TX2Device 1Sending data todevice 3 on theprimary channelDevice 2Sending da

Comments to this Manuals

No comments